ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution

خواص اساسی
محل مبدا: چین
نام تجاری: ESTEL
گواهینامه: CE UL FCC
املاک تجاری
حداقل مقدار سفارش: 1 مجموعه
قیمت: USD300-USD1000
شرایط پرداخت: T/T، وسترن یونیون
توانایی تامین: 5000
خلاصه محصول
ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution The ET48300-005 is a 5U rack-mounted DC telecom power system developed for communication sites that need dependable -48V power, organized load distribution and battery backup in a compact ...

جزئیات محصول

برجسته کردن:

48V telecom power system with 300A

,

5U 18kW DC power system

,

telecom power system with rectifiers

Solar Array: 24 عدد پنل خورشیدی 580 واتی
Input Capacity: 1 × 63a/2p
Thd: <1،5 ٪ در بار مقاومت
Dc Load Breakers: 30 موقعیت
Efficiency: 90 ≥
Certifications: ISO9001، CE، RoHS
Package: کارتن
Poweroutput: 10 کیلو وات - 100 کیلو وات
Ac Frequency: 50 هرتز ، 60 هرتز یا آخرین همگام سازی
Load Protection: LLVD، BLVD
Protectionfeatures: اضافه ولتاژ، اضافه جریان، اتصال کوتاه، بیش از حد دما
Dc Current Max: 53.5 VDC / 43 - 58 VDC
Dc Output Breakers: 4
Frequency: ۴۵ ۶۶ هرتز
Industrial Ac Input: تک فاز برای هر یک از یکسو کننده ها
توضیحات محصول

 

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution

 
 
The ET48300-005 is a 5U rack-mounted DC telecom power system developed for communication sites that need dependable -48V power, organized load distribution and battery backup in a compact cabinet space. It is positioned as an 18kW / 300A class solution, using six 3kW rectifier modules to provide stable DC output for transmission equipment, access devices, switches and base-station loads.
 
This model is suitable for sites using 220VAC single-phase input, making it easier to deploy in equipment rooms or access network cabinets where three-phase power is not available. The system integrates AC input protection, AC surge protection, rectification, battery breakers, LLVD/BLVD load outputs, DC SPD, LCD monitoring and communication terminals into one front-service platform. The front panel layout allows technicians to check breaker status, controller alarms and wiring terminals without removing the system from the rack.

Product Features 18kW 48V 300A DC Telecom Power System

 

18kW modular capacity: Six 3kW rectifiers support flexible configuration and online maintenance.

 

300A DC output class: Suitable for medium to high-load telecom power distribution.

 

Single-phase AC input: Designed for 220VAC sites with 1 × 100A/2P input protection.

 

Clear load separation: LLVD and BLVD branches help divide priority and non-priority equipment.

 

Battery protection: Two 125A battery breakers support backup battery connection and isolation.

 

Surge protection: Integrated AC SPD and DC SPD improve system resistance to transient overvoltage.

 

Remote monitoring support: LCD controller with RS485, SNMP, dry contacts, AI/DI signal inputs.

 

Front maintenance design: Rectifier and controller are hot-pluggable for faster field replacement.

 

Application Scenarios 18kW 48V 300A DC Telecom Power System

 
The ET48300-005 is suitable for wireless base stations, transmission networks, fiber access sites, enterprise communication rooms, microwave stations, telecom cabinets and backup DC power systems requiring stable -48V distribution with battery management.
 

Technical Parameters 18kW 48V 300A DC Telecom Power System

 

Model: ET48300-005

 

Type: 3–18kW 5U Subrack

 

Maximum Current: 300A

 

Dimensions: 482.0(W) × 350.6(D) × 5U(H)

 

Weight: ≤22kg without rectifiers

 

Installation: 19-inch rack or cabinet

 

Cabling: Top inlet and top outlet

 

Protection Level: IP20

 

AC Input: 220VAC single phase

 

Input Capacity: 1 × 100A/2P

 

Frequency: 45–65Hz, rated 50/60Hz

 

AC SPD: 20kA/40kA, 8/20μs

 

DC Output: -43V to -58VDC, rated -53.5VDC

 

Maximum Capacity: 18kW, 6 × 3kW

 

Battery Breakers: 2 × 125A/1P

 

LLVD: 2 × 32A/1P + 2 × 40A/1P + 3 × 63A/1P

 

BLVD: 2 × 6A/1P + 2 × 10A/1P + 2 × 16A/1P

 

DC SPD: 10kA/20kA, 8/20μs

 

Rectifier Efficiency: >96%

 

Power Factor: ≥0.99

 

Operating Temperature: -40°C to +75°C

 

Humidity: 5%–95%, non-condensing

 

Altitude: 0–4000m

 

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 0

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 1

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 2

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 3

محصولات مرتبط
  • 28U کابینت برق داخلی با سیستم اصلاح کننده UPS محفظه ذخیره انرژی باتری

    28U کابینت برق بیرونی با سیستم اصلاح کننده UPS باتری ذخیره انرژی 1مقدمه کوتاه: کابینت های مخابراتی بیرونی معمولاً دارای طیف وسیعی از ویژگی ها برای اطمینان از حفاظت و عملکرد تجهیزات مخابراتی هستند. برخی از ویژگی های مشترک کابینت های مخابراتی بیرونی عبارتند از: طراحی ضد آب و هوا: کابینت های بیرونی بر...
  • کابینت برق در فضای باز ، کابینت مخابرات در فضای باز با سنسور آب / سنسور درب

    کابینت برق در فضای باز ، کابینت مخابرات در فضای باز با سنسور آب / سنسور درب 1. شرح کابینت یک کابینت محفظه است.خنک کننده کابینت از تهویه مطبوع و مبدل حرارتی برای اطمینان از عملکرد عادی تجهیزات در محدوده دمای پایدار استفاده می کند تا عمر مفید تجهیزات بسیار طولانی تر و عملکرد آنها پایدارتر شود. 2. برنا...
  • کنترل دما کابینت مخابرات در فضای باز IP55 حفاظت از ورود با سوکت ژنراتور

    کنترل دما کابینت برق در فضای باز / کابینت مخابرات در فضای باز با سوکت ژنراتور 1. مشخصات (1) پارامترهای فنی حفاظت از ورود: IP55 درجه B اثبات رعد و برق: اسمی: 60KA ، حداکثر .: 100KA دما: دمای کار: -40 ° C ~ +55 ° C دمای ذخیره سازی: -50 C ~ + 70 C دمای حمل و نقل: -50 C ~ +70 C رطوبت نسبی: 5 ~ ~ 100 فشا...
  • Emerson Rectifier / Battery Outdoor Power Cabinet Sandwich Structure Panel IP55

    کابینت منبع تغذیه پانل ساندویچ سازه در فضای باز با رکتیفایر امرسون و باتری 1 توضیحات محصول 1.1 ظاهر پس از نصب کابینت، همانطور که در شکل 1 و شکل 2 نشان داده شده است شکل 1 شکل 2 1.2 پیکربندی کابینت پیکربندی کابینت یکپارچه فضای باز این پروژه به شرح زیر است: نوع کابینت پیکربندی تعداد مشخصات فنی کابینت ا...

درخواست ارسال کنید